18 TEAC Corporation
5. Return Command Detail
5-1. TIME DATA
When the Time mode is set to other than OFF with TIME DATA SEND SELECT command [3F],
controlled device outputs the time data in specified form by TIME DATA SEND SELECT command [3F].
Command 88
Data 8 bytes
Description Remarks
Data 1 Tens digit of minutes
Data 2 Units digit of minutes
Data 3 Thousands digit of minutes
Data 4 Hundreds digit of minutes
Data 5 Tens digit of seconds
Data 6 Units digit of seconds
Data 7 Tens digit of frames
Data 8 Units digit of frames
5-2. INFORMATION RETURN
Transmitted in response to an INFORMATION REQUEST command [0F].
Returns the software version of the controlled device.
Command 8F
Data 4 bytes
Request command INFORMATION REQUEST [0F]
Data 1 Tens digit of software version Sample data for Data 1 - Data 4
Data 2 Units digit of software version 0100 Version 1.00
Data 3 1
st
decimal digit of software version
Data 4 Hundreds digit of software version
5-3. AUTO CUE LEVEL RETURN
Transmitted in response to an AUTO CUE LEVEL PRESET command [20] with the request data ([FF])
to show the currently set Auto Cue level.
Command A0
Data 2 bytes
Request command AUTO CUE LEVEL PRESET [20]
Data 1 Data 2 Description Remarks
0 0 -24dB Auto Cue detect level is set to 24dB
0 1 -30dB Auto Cue detect level is set to 30dB
0 2 -36dB Auto Cue detect level is set to 36dB
0 3 -42dB Auto Cue detect level is set to 42dB
0 4 -48dB Auto Cue detect level is set to 48dB
0 5 -54dB Auto Cue detect level is set to 54dB
0 6 -60dB Auto Cue detect level is set to 60dB
0 7 -66dB Auto Cue detect level is set to 66dB
0 8 -72dB Auto Cue detect level is set to 72dB