TASCAM MMR-8 Owner’s Manual • Appendix D • Cable Information
144
ANALOG INPUT & OUTPUT Connectors pinouts
PIN # Signal Description PIN # Signal Description
1 Channel 8 + signal 14 Channel 8 - signal
2 Channel 8 ground 15 Channel 7 + signal
3 Channel 7 - signal 16 Channel 7 ground
4 Channel 6 + signal 17 Channel 6 - signal
5 Channel 6 ground 18 Channel 5 + signal
6 Channel 5 - signal 19 Channel 5 ground
7 Channel 4 + signal 20 Channel 4 - signal
8 Channel 4 ground 21 Channel 3 + signal
9 Channel 3 - signal 22 Channel 3 ground
10 Channel 2 + signal 23 Channel 2 -signal
11 Channel 2 ground 24 Channel 1 + signal
12 Channel 1 - signal 25 Channel 1 ground
13 No connection
NOTES:
1. 25-pin D-subminiature female connector (DB-25). The pinouts follow the
TASCAM DA-88 configuration. Each input is differential with the (+) inputs
being the non-inverting input and the (-) being the inverting input.
2. Input impedance is 10k ohm.
3. Output impedance is 75 ohm.
4. Max load 12.28 VRMS
BIPH (Biphase) Connectors pinout
PIN # Signal Description
1 Ground
2 Phase-A
3 Phase-B
4 Phase-B
5 Phase-A
6 Ground
NOTES:
1. RJ12 compatible Modular Plug, 6 Position, 6 Conductor.: Flat Wire - Stranded.
Round Wire - Stranded. DataComm Warehouse (http://kerry.warehouse.com/)
can supply these parts, however, many other sources available.
2. The four Biphase Inputs are selected one-at-a-time by the Sync Group setting.
3. Not intended for public telecommunication network.